<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-14 04-32-54
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.60 MHz 4/5, 72 dBuV P3 SR
Pilot RDS Phase Difference
6.5 kHz 3.1 kHz 76 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
8 kHz 27 kHz 8248 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-3,6 dBr -1,25 dBr 0,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"P3 SR " E203 12 (Easy M) 0 1 1 9 3:32, 14.07.2025
RT
"Nationalteatern - Barn Av Vår Tid lsson d) The Time Of My Life "
AF EON
97.9, 99.0, 99.4, 100.5 MHz E201, E402, E224
FM Scope Max at: 27 kHz MIN: 8 kHz % above 76 kHz: 0,0000 Acquired: 2025/07/14 4.31.51 Total samples: 8248 Equivalent time: 0:06:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 0,2 dBr MIN: -3,6 dBr AVE: -1,25 dBr % above 12,2 dBr: 0,0 Last value: -1,5 dBr (2025/07/14 4.31.51) 04.18 04.20 04.22 04.24 04.26 04.28 04.30 -4 -3 -2 -1 0 1 Pm [dBr]